A.worn gland sealing shaft
B.worn wearing rings
C.a bent shaft
D.reversed pump coupling
您可能感興趣的試卷
你可能感興趣的試題
A.A power end and fluid end
B.A propeller and educator
C.A volute and impeller
D.A turbine and piston
A.water seal pipe is plugged
B.pump is not primed
C.seal ring is improperly located
D.impeller is flooded

最新試題
If the relief valve on the discharge side of a hydraulic pump lifts, the cause could be ().
A pressure drop through the refrigerant liquid line may cause ().
An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().
A gradual decrease in the discharge pressure of an operating hydraulic pump can be caused by ().
When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().